Zareba Security offers several choices of control systems for the Induced Pulse perimeter system. From the robust and expandable IP6000 control system, to a simple single-zone controller for small zones, we have the appropriate control system for any perimeter.  IP6000 - Expandable Multi-Zone
Z6 Six-Zone
IP602 Two-Zone
M2000 Single-Zone
BIP200 Single Zone



IP6000 Multi-Zone Control System
Deters and delays intruders with a short, safe high-voltage shock. Detects attacks by monitoring the fence for cut wires and shorting.

The IP6000 Security Electric Fence System provides greater control and enhanced performance at the point of entry. The system is designed to suit all applications, from the smallest industrial compound up to major project applications.

The IP6000 system is based on a main control processor unit with remote or local outstations communicating with a central controller via a common data network. The central processor may be controlled by a keypad operated system or through a Zareba “smart” PC based system.
 Induced Pulse Control Options Diagram

IP6000 Multi-Zone Control System Features:
  • Simply install/upgrade with module to module interconnectors for power supply and signal wires
  • Safe primary power supply of 18V AC allows hook-up to its own power supply or remotely via short runs of low voltage cable
  • Secondary 12V DC battery back-up
  • Multiple user codes
  • Time and date event logging
  • Works effectively with either Zareba keypad operated system or Zareba PC based headend system
  • Incidence reporting via SMS messaging to cell phone
  • Fault analysis and engineering diagnostics
  • Individual zone operation and isolation
  • Built in a weatherproof IP66 fiberglass enclosure

 

Technical Specs:

Supply Voltage 110-230V / 50-60 Hz main
12V DC Backup
Stored Energy 1.2 j Stored per Zone
HV Output 9 KV (no load)
Contact ratings of funtion relays 30V DC / 500 mA

Aux DC Supply Out 12-15V DC / 100 mA
Enclosure 23 5/8" x 15 3/4" x 7 7/8"
600mm x 400mm x 200mm
Grey / Fiberglass (IP66)




Induced Pulse Z6 Control Cabinet  Z6 Six Zone Control System
Ideal for enclosures up to 2,950 ft (900m) using a 30-wire six zone fence. The unit is built around a micropressor controlled alarm system providing eight inputs and a tamper loop. Two inputs are programmable by the end user for connection to a variety of intruder detection equipment. The unit can be armed and disarmed by various methods of exit/entry conrol inculding multiple keypads. Clean contact outputs are given for controlling auto-dialer and other alarm activation equipment. Multiple units can be cotrolled from a master panel.

Z6 Six Zone Control System Features:

  • Steel IP66 enclosure
  • Standby for 6 hours
  • Six HV zone outputs
  • 8Kv no load output
  • 3.5Kv @500 Ohms
  • 1.8ms output pulse
  • 1.5s pulse interval
  • Four clean contacts



Induced Pulse IP602 Control Cabinet IP602 Two Zone Energiser/Monitor Unit
This unit will power two 165 ft (50m) 30-wire fence zones. More than one energiser can be used for multiple zones. These are controlled from a master unit which can be locally or remotely located. This system has the advantage of being extended as customer requirements grow. Individual zones can be switched off or on, allowing ease of maintenance.

IP602 Two Zone Features:

  • 12V DC backup
  • 9.0Kv no load output
  • 1.2s pulse interval
  • Three clean contacts
  • Fiberglass IP66 enclosure



Induced Pulse M2000 Control Cabinet M2000 Single Zone System
Ideal for enclosures of up to 1,312 ft (400m) using a 30 wire fence. The unit is built around a microprocessor controlled alarm system providing eight detection inputs and a tamper loop. Seven inputs are programmable by the end user for connection to a variety of intruder detection equipment. The unit can be armed and disarmed by various methods of exit/entry control including multiple keypads. Clean contact outputs are provided for controllng auto-dialers and other alarm activation equipment.

M2000 Single Zone Features:

  • Steel IP66 enclosure
  • Standby for six hours
  • 8Kv no load output
  • 5Kv @500 Ohms
  • 2ms output pulse
  • 1.0s pulse interval
  • Four clean contacts



Induced Pulse BIP200 Single Zone System BIP200 Single Zone System
The BIP200 is a low cost unit giving basic alarm functions. It works on a closed loop system. Any break in the loop or loss of voltage at the sensing terminal will cause the alarm to sound. Ideally suited for use in small compounds or to power wall capping in domestic and business situations. It will power up to 3,280 ft (1,000m) of steel fence wire.

BIP200 Single Zone Features:

  • IP44 plastic housing
  • 12V DC powered
  • Front panel status indication
  • 8.0Kv no load output
  • 3.5Kv @ 500 Ohms
  • 2.3ms output pulse
  • 1.0s pulse interval
  • 2-20 minute alarm timer
  • Latch/No Latch alarm output